Model |
ZLS240 |
|
Input parameter |
Input voltage range |
85-264VAC or 88-370vdc
Note: the maximum input can reach ac315v / dc440v; Pf value decreases (AC) beyond rated value
|
Input current |
2.5A/115VAC ; 1.3A /230VAC |
|
Frequency range |
47 - 63 Hz |
|
Conversion efficiency |
92%typ |
|
Surge current |
8Atyp /115VAC 15Atyp/230VAC (冷态时) |
|
Leakage current |
2mA max/2 4 0VAC |
|
Output parameters |
Output DC voltage |
One way 12V/15V/24V/48V |
Rated output current |
I=240W/Vout |
|
Output current range |
0 ~ IN |
|
Rated power |
240W |
|
Output ripple |
< 100mVp-p |
|
Voltage adjustment range |
-10%/+15% |
|
Allowable voltage tolerance range |
+/-1.0% |
|
Voltage regulation rate |
+/-1.0% |
|
Load adjustment rate |
+/-1.0% |
|
Start, rise, hold time |
500ms, 70ms, 30ms Full load condition |
|
Protection function |
overload protection |
Protection type: constant current protection, current range 110 ~ 140% (rated value), output voltage less than 80% (±
5%), the undervoltage indicator light is on, the fault alarm relay is closed, and it will reset automatically after the fault disappears. Precautions: avoid the power supply in short circuit or overcurrent state for more than 5min
|
Overvoltage protection |
120%-140%Vout/Cut off type |
|
High temperature protection |
100℃+/-5℃ (PTC) Detect the internal temperature of transformer
Protection type: high temperature shutdown protection, automatic reset after temperature drop
|
|
Environmental requirements |
Working environment temperature and humidity |
-25 ~ +60℃ / 20 ~ 90% Relative humidity no condensate |
Storage temperature, humidity |
-40 ~ +85℃, 10 ~ 95% RH |
|
Temperature coefficient |
+/-0.03% (0 ~ 50℃) |
|
Vibration test |
10 ~ 500Hz, 2G 10min/1cycle, 60min. 每次沿 X, Y, Z 轴 |
|
Safety regulations
And EMC
|
Safety standards |
Satisfy UL508, TUV EN60950-1 |
Impact strength |
I/P-O/P: 2.5KVAC I/P-FG: 2.5KVAC O/P-FG: 0.5KVDC |
|
Insulation resistance |
I/P-O/P, I/P-FG, O/P-FG 100M Ohms/500VDC |
|
EMI insulation resistance |
Satisfy EN55011(CISPR11), EN55022(CISPR22), Class B |
|
Harmonic current |
Satisfy EN61000-3-2,3 |
|
EMS immunity |
Satisfy EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024,
EN61000-6-2(EN50082-2) Heavy industry standard, AGB / T 14598.13 fast transient level IV, IEC 60255-22-5 surge level IV
|
|
Other |
Mean time between failures |
120Khrs min. MIL-HDBK-217F (25℃) |
Size |
62*124*108mm (W * H * D) |
|
Packing |
0.85Kg; 18pcs/11kg/1.1CUFT |
|
Remarks |
1. Parameters not specially indicated are measured under 230V AC input, rated load and ambient temperature of 25 ℃.
2. Ripple or noise is measured by an oscilloscope with a band of 20MHz and a 0.1uF and 47uF capacitor connected in parallel with 12 "twisted pair. 3. Tolerance: including startup tolerance, voltage regulation rate and load regulation rate. 4. The power supply is considered as a component installed on the final equipment. The final equipment must reconfirm that it meets EMC's directives.
|
|
Wuxi Zhongli Electronic Technology Co., Ltd
Address: 30-41 Huixi Road, Liangxi District, Wuxi City
Tel: 13952472300 / 15995281687
Website: www.wxzldz.com
E-mail:wanglikai@wxzldz.com